RAJBASI.CO.UK ≡ Male Pills Bags Pet Baskets Mudcloth
  • Cold Air Duct Insulation

  • MAXFLEX FR Black Rubber Insulation Sheet

MAXFLEX FR Black Rubber Insulation Sheet

$37.5 $49.88
MaxFlex FR MAXFLEX FR Black Rubber Sheet Insulation is ideal for cold applications with operating temperatures from -57 to 125°C, offering superior low thermal conductivity compared to other insulation types. {�PTION%}   ค่าการนำความร้อน Thermal Conductivity Thermal conductivity indicates how much heat a material can transmit. A higher value means the material can transfer heat more quickly and efficiently. Therefore, good thermal insulation should have a low thermal conductivity value, ideally close to 0. MaxFlex FR Black Rubber Sheet has low thermal conductivity at 0.031 W/m.K at 0°C, making it excellent for cold applications with minimal energy loss. MAXFLEX FR Black Rubber Sheet is ideal for cooling systems and applications requiring cleanliness.   การต้านทานรังสีUV MaxFlex FR’s EPDM rubber composition provides superior UV resistance. Testing at Department of Science Service with UVB-313 at 60°C for 8 hours showed no changes. This ensures that when installed and exposed to sunlight, it can withstand without cracking. However, if MaxFlex FR black rubber insulation is installed outdoors and exposed to sunlight and weather conditions, it should be jacketed to extend the material’s lifespan due to weather and biological factors. การดูดซับน้ำ Water Absorption The water absorption property of materials in insulation applications should be low. In black rubber insulation applications that encounter low temperatures, condensation can easily occur, which can cause pipe corrosion or damage to other materials. Uninsulated pipes develop surface condensation. Therefore, black rubber insulation or other types of insulation should not absorb water. The water absorption of MaxFlex FR black rubber insulation is less than 0.05% by volume, which is extremely low – practically non-absorbent.   ประสิทธิภาพเกี่ยวกับเพลิง Fire Performance Building systems have strict requirements for materials, especially regarding flammability. Black rubber insulation is used in water pipe systems or air conditioning systems, which run throughout the building. If the material attached to the pipes catches fire, it could spread quickly throughout the building. Insulation in pipe systems or air conditioning systems must therefore be fire-resistant. We have tested the fire resistance of MaxFlex FR black rubber insulation according to many standards including BS 476 Part 7, UL 94, ASTM D635, and it has been confirmed as a non-flammable material. When ignited, the flame will self-extinguish.     Air Duct Insulation Thickness Selection Table Ambient Condition Dew Point Operating Temperature (Cool Air Temperature) 17oC 15oC 13oC 10oC 7oC 5oC 27oC , 50% RH 16oC 6 mm 6 mm 6 mm 9 mm 9 mm 9 mm 27oC , 70% RH 21oC 6 mm 6 mm 9 mm 9 mm 13 mm 13 mm 30oC , 70% RH 24oC 9 mm 9 mm 9 mm 9 mm 13 mm 16 mm 30oC , 75% RH 25oC 9 mm 9 mm 13 mm 13 mm 19 mm 19 mm 32oC , 80% RH 28oC 16 mm 16 mm 25 mm 25 mm 25 mm 32 mm 34oC , 85% RH 31oC 19 mm 25 mm 25 mm 32 mm 32 mm 38 mm 35oC , 85% RH 32oC 25 mm 25 mm 32 mm 38 mm 50 mm 50 mm 35oC , 90% RH 33oC 32 mm 32 mm 38 mm 50 mm 56 mm 56 mm   MAXFLEX FR Air Conditioning Pipe Insulation Properties Table Physical Properties MAXFLEX FR TEST METHOD Material EPDM or NBR Blend with additive TGA / DSC Cell Structure Closed Cell Structure – Flexibility Excellent – Density 3 – 6 lbs/ft3 (48 – 96 kg/m3) ASTM D1667 Service Temperature -57oC – 125oC -70oF – 257oF Can withstand temperature as high as 125 oC Maxflex becomes hard at -57oC But can be used even at -200oC ASTM C411 Ozone & UV Resistance No Crack ASTM D1171 & ASTM G154 Water Absorption ≤ 1.5% by weight ≤ 0.05% by volume ASTM D1056 ASTM C209 Water Vapor Diffusion Resistance (µ Value) µ ≥ 12,000 EN 12086 DIN 52615 Water Vapor Permeability (g/Pa.s.m) ≤ 0.10 perm-in (≤1.15 x 10-10) ASTM E96 Anti Microbial Fungi Resistance Compliance with requirement ASTM E2180 ASTM G21 Heat Stability at 200oF (7 Days) (% Shrinkage) ≤ 3.5% Respectively ASTM C534 Fire Performance (Fire Retardant) Class V-0 Self-Extinguishing B2 0,0,0,5 Compliance with requirement UL 94 ASTM D635 DIN 4102 AS 1530.3 NFPA 90A & NFPA 90B Fire Index Index 5.3 EMPA SWISSI Flame spread / Smoke Developed 25 / 50 ASTM E84 Surface Spread of flame Class 1 BS476 Part 7 Fire Propagation – Total Index of Performance (I) – Sub Index (i1) Class 0 ‹ 12 ‹ 6 BS476 Part 6 Smoke Toxicity – Smoke Density Satisfies max allowable concentration for the following combustion gases CO, HCI , HF , HBr , HCN , Nox , SO2 Dm ≤ 100 ISO 5659-2:2017 RoHS I & II Test Compliance with requirement International Marine Organization (IMO) Nitrosamine Content Not detected BS EN 12868 Ozone Depleting Substances (ODS) – CFCs, HCFCs Not detected USEPA 5021A / 8260C Volatile Organic Chemical Emission (VOCs) Not detected CDPH EHLB STANDARD METHOD V1.2 and VOC Emission Test After 14 Day Formaldehyde Content Not Detected ISO 17226-1 Asbestos Dust & Fiber Not Detected Not Detected EPA600/R Odour Test at 23oC , 40oC Grade 1.5, Grade 2.0 FLTM BO 131-03 Corrosion (Copper, Stainless Steel) Non Corrosive DIN 1988 Sound Absorption Coefficient 0.65 NRC ASTM C423 Noise Reduction Coefficient Maximum 36.3 dB(A) DIN 52219 (19 mm thickness)   Black Rubber Sheet Thermal Conductivity Table Mean Temp -40oF (-40oC) -22oF (-30oC) -4oF (-20oC) 32oF (0oC) 75oF (24oC) 90oF (32oC) 104oF (40oC) 122oF (50oC) K-Value 0.20 0.029 0.21 0.030 0.22 0.031 0.23 0.033 0.24 0.035 0.25 0.037 0.26 0.038 0.27 0.09   Black Rubber Sheet Sound Absorption Coefficient at Frequency Table Frequency (Hz) 125 250 500 1000 2000 4000 NRC Absorption Coefficient 0.06 0.14 0.66 0.90 0.91 0.90 0.65
Cold Air Duct Insulation

Cold Air Duct Insulation

  • MAXFLEX FR Black Rubber Insulation Roll
    $68.69 $105.1
  • MicroFiber Glass Wool Insulation for Air Conditioning System Wrapping FR Model
    $57.77 $97.63
  • MAXFLEX FR Black Rubber Insulation Sheet
    $37.5 $49.88
  • MAXFLEX FSK Pipe Insulation for Indoor Use
    $56.18 $84.83
  • MicroFiber Glass Wool Insulation for Air Conditioning Systems, FSF Model
    $66.62 $99.26

© 2026 - RAJBASI.CO.UK