Round pipe support foam, MaxFix model for pipe hanging points
$46.23
$75.82
MaxFix pipe support foam Black rubber insulation is suitable for cold applications, with an operating temperature range of -57 to 125 degrees Celsius. It has a very low thermal conductivity, giving it an advantage over other types of insulation for low-temperature applications. Thermal Conductivity Thermal conductivity indicates how much heat a material can transmit. A higher value means the material can transfer heat more quickly and efficiently. Therefore, good thermal insulation should have a low thermal conductivity value, ideally close to 0. MaxFlex FR black rubber insulation has low thermal conductivity, suitable for low-temperature applications. At 0°C, its thermal conductivity is only 0.031 W/m.K, which is very low, allowing it to retain cold within the system effectively and minimize energy loss. UV Resistance The properties of MaxFlex FR black rubber, made from EPDM rubber, give it higher UV resistance than other materials. We tested UV resistance with the Department of Science Service using UVB-313 radiation at 60°C for 8 continuous hours. The results showed no changes to the MaxFlex FR insulation. This ensures that when installed and exposed to sunlight, it can withstand without cracking. However, if MaxFlex FR black rubber insulation is installed outdoors and exposed to sunlight and weather conditions, it should be jacketed to extend the material’s lifespan due to weather and biological factors. Water Absorption The water absorption property of materials in insulation applications should be low. In black rubber insulation applications that encounter low temperatures, condensation can easily occur, which can cause pipe corrosion or damage to other materials. Therefore, black rubber insulation or other types of insulation should not absorb water. The water absorption of MaxFlex FR black rubber insulation is less than 0.05% by volume, which is extremely low – practically non-absorbent. Fire Performance Building systems have strict requirements for materials, especially regarding flammability. Black rubber insulation is used in water pipe systems or air conditioning systems, which run throughout the building. If the material attached to the pipes catches fire, it could spread quickly throughout the building. Insulation in pipe systems or air conditioning systems must therefore be fire-resistant. We have tested the fire resistance of MaxFlex FR black rubber insulation according to many standards including BS 476 Part 7, UL 94, ASTM D635, and it has been confirmed as a non-flammable material. When ignited, the flame will self-extinguish. Product List MaxFlex Black Rubber Insulation Tube Table MAXFLEX FR Insulation Tube : 2 Meter/Piece ID of MAXFLEX FR Tube Pipe Size : mm. (Inch) Product mm. Inch Copper Pipe Steel Pipe PPR PVC 6 mm. Wall (1/4″) 9 mm. Wall (3/8″) 13 mm. Wall (1/2″) 19 mm. Wall (3/4″) 25 mm. Wall (1″) 32 mm. Wall (1-1/4″) 38 mm. Wall (1-1/2″) 50 mm. Wall (2″) 6 1/4″ 6 / / / 9 3/8″ 9 / / / / 13 1/2″ 13 6 (1/4″ IPS) 20 (1/2″) 6 / / / / / 16 5/8″ 16 9 (3/8″ IPS) 25 (3/4″) 9 / / / / / / / 19 3/4″ 19 / / / / / / / / 22 7/8″ 22 13 (1/2″ IPS) 32 (1″) 13 / / / / / / / / 25 1″ 19 (3/4″ IPS) / / / / / / / 28 1-1/8″ 28 19 / / / / / / / 32 1-1/4″ 40 (1-1/4″) / / / / / / / 35 1-3/8″ 25 (1″ IPS) 25 / / / / / / / 38 1-1/2″ / / / / / / / 42 1-5/8″ 42 32 (1-1/4″ IPS) 50 (1-1/2″) 32 / / / / / / / 45 1-3/4″ / / / / / / / 48 1-7/8″ 38 (1-1/2″ IPS) 38 / / / / / / / 51 2″ / / / / / / / 54 2-1/8″ 54 / / / / / / / 57 2-1/4″ / / / / / / / 60 2-3/8″ 51 (2″ IPS) 51 / / / / / / / 64 2-1/2″ 63 (2″) / / / / / / 67 2-5/8″ 67 / / / / / / 73 2-7/8″ 64 (2-1/2″ IPS) 64 / / / / / / 76 3″ 76 75 (2-1/2″) / / / / / / 80 3-1/8″ 80 / / / / / / 82 3-1/4″ / / / / / / 90 3-1/2″ 76 (3″ IPS) 90 (3″) 76 / / / / / / 92 3-5/8″ 92 / / / / / / 98 3-7/8″ / / / / / / 102 4″ 90 (3-1/2″ IPS) 90 / / / / / / 105 4-1/8″ 105 / / / / / / 115 4-1/2″ 102 (4″ IPS) 110 (4″) 102 / / / / / / 130 5-1/8″ 130 125 (5″) / / / / / / 140 5-1/2″ 127 (5″ IPS) 127 / / / / / / 165 6-1/2″ 152 (6″ IPS) 160 (6″) 152 / / / / / MaxFlex Black Rubber Insulation Roll Table Thickness (mm.) Size (m. x m.) Area (sq.m) 3 1.22 x 15.00 18.3 6 1.22 x 21.9 26.7 9 1.22 x 15.2 18.5 13 1.22 x 10.9 13.4 16 1.22 x 9.7 11.8 19 1.22 x 7.0 8.5 25 1.22 x 5.4 6.7 32 1.22 x 4.0 4.9 38 1.22 x 3.0 3.7 50 1.22 x 2.4 2.9 MaxFlex Black Rubber Insulation Sheet Table Thickness (mm.) Size (m. x m.) 3 1.22 x 0.91 6 1.22 x 0.91 9 1.22 x 0.91 13 1.22 x 0.91 16 1.22 x 0.91 19 1.22 x 0.91 25 1.22 x 0.91 32 1.22 x 0.91 38 1.22 x 0.91 50 1.22 x 0.91 Technical Data Table Features Maxflex FR Test Standard Material EPDM Blend with additive TGA / DSC Material Structure Close Cell / Excellent – Density 3-4 lbs/ft3 (48-96 kg/m3) ASTM D1667 Operating Temperature -57C – 125C Maxflex become hard at -57C -70F – 257 F But can be use even -200C Maximum Temperature Can withstand temperature as high as 125 C ASTM C411 Ozone Resistance No Crack ASTM D1171 UV Resistance No Crack ASTM G154 Water Absorption <= 1.5% by Weight <= 0.05% by Volume ASTM D1056 Water Vapor Transmission Resistance Mu > ≥ 12,000 ASTM C209 Fungal and Microbial Resistance Compliance with requirement ASTM E2180, ASTM G21 Dimensional Stability under Heat (% Shrinkage) At 200 F (7 Days) <= 3.5% Respectively ASTM C534 Fire Performance Class V0 UL 94 FM Approved FM Approval Self-Extinguishing ASTM D635 B2 SIN 4102 0, 0, 0, 5 AS 1530.3 Compliance with requirement NFPA 90A & NFPA 90B – Flame Spread / Smoke Developed 25/50 ASTM E84 – Reaction to Fire Compliance with EURO Class E EN ISO 11925 – Fire Index Index 5.3 EMPA SWISSI Surface Flame Spread Class M1 FRANCE AFNOR NF P92 501 Class 1 BS 476 Part 7 Material Flame Spread Class 0 BS 476 Part 6 – Total Index of Performance (I) Less than 12 – Sub Index (i) Less than 6 Smoke Toxicity Satisfies max allowable concentration for the following combustion gases CO, HCl, HF, HBr, HCN, NOx, SO2 ISO 5659-2:2017 – Smoke Density Dm < ≤ 100 Compliance with requirement International Marine Organization (IMO) RoHs Test Compliance with requirement Certain Hazardous Substances in Electrical and Electronic Equipment, 2011/65/EU and its amendment Directive (EU) 2015/863 Nitrosamine Content Not detected BS EN 12868 Ozone Depleting Substances (ODS) Not detected USEOA502 1A/8260C – CFCs, HCFCs Formaldehyde Content Not detected ISO 17226-1 Asbestos / Dust & Fiber Not detected EPA600/R Odor Test at 23 C, 40 C Grade1.5, Grade2.0 FLTM BO 131-03 Corrosion of Copper and Stainless Steel Non Corrosive Din 1988 Noise Reduction Max. 36.3 dB(A) DIN 52219 (19 mm. Thickness)
Pipe Support Foam And Rubber Pipe Supports